ThermoCube 400L to 600L

Thermocube 400L by Solid State Cooling Systems

Liquid Cooled, Recirculating Chiller

Current Customer Applications

  • semiconductor fab equipment temperature control
  • laboratories with recirculating house chilled water
  • laser cooling
  • gas bottle temperature control
  • scanning electron microscopes

Solid State Cooling Systems

Download PDF Brochure
Request Instant Quote for ThermoCube

Overview

Why choose ThermoCube 400L or 600L?

  • Reliable, Refrigerant-Free Thermoelectric Technology: With lifetimes exceeding 200,000 hours, the thermoelectric modules at the core of this chiller make for ultra-high intrinsic reliability.
  • Compact Size: just 12” (30 cm) on a side
  • Precise Temperature Control: ThermoCube's digital PID controller holds to ±0.05°C, even near ambient
  • Optimized for Modest Heat Loads
  • Versatile: For use with fluorinert, glycol solutions or water
  • Energy Efficient: ThermoCube's thermoelectric modules are powered by variable voltage power supply that provides the minimum power required to control temperature at set point, so ThermoCube only draws as much power as needed (typically <200 W AC).
  • Whisper-Quiet: as low as 49 dBA
  • Virtually Vibration-Free
  • Worldwide Power Compatibility, Universal Input Standard
  • Easy-to-Use controller for fixed temperature control or temperature cycling
  • Liquid-Cooled: For use with recirculated filtered treated industrial water
  • High Pressure Pumps Standard: ThermoCube's standard pump is capable of delivering up to 50 psi for laser diode and other high-pressure applications. Low-pressure pumps are also available.

Performance

tcube 400-600l coolingcapacity lowres thermocube pumpcurve lowres

Specifications

Operating Range: -5 to 50 °C standard range
(down to -10 °C with low temp option)
(up to 65 °C with high temp option)
      House water: 1 gpm recirculated filtered treated industrial water
Repeatability: + 0.05 °C, even near ambient House Fittings: 3/8” CPC standard,
John Guest or Swagelok available
Cooling Capacity:
400 or 600 Watts at 20 °C into 20 °C
house chilled water
(also see Performance Curves)
 Size (L x W x H): 12.75 x 11.25 x 12.75"
(32.4 x 28 x 32.4 cm)
Modes: Fixed setpoint, cycling Weight: 28 lbs. (13 kg) with basic options
Noise: 48 dBA at 3 feet (pump dependent) Power: 115-230 VAC, 50 or 60 Hz, 7A - 5A
Coolant: Water/glycol mixture, industrial water,
Fluorinert or Galden with optional pump
Standards: CE, TUV listed to CSA/UL 61010-1
Coolant Fittings: 1/4" CPC standard,
John Guest or Swagelok available
Alarms: TTL (temp and system failure), fluid level
Pumps: See Pump Curves (Performance tab) for choices Communications: RS232
Filter: Optional 5 μm external fluid filter Warranty:  1-2 years (pump dependent)

Configuration

The following components are included in the standard ThermoCube chiller configuration. However, we regularly work with OEM customers to develop specialized or unique ThermoCube configurations.

Capacity

Options Purpose Standard Operating Temperature Range Standard Operating Temperature Range
400 L Recirculating liquid chiller, cooled by house chilled water heat load up to 400 W (1360 BTU/hr) 5 to +50 °C 41 to 122 °F
600 L Same as above, up to 600 W  5 to +50°C 41 to 122°F



Pumps

Option Purpose Noise Pressure Allowed Process Coolant MTBF (manufacturer's) Pump Warranty
1 lpm Magnetic Drive Gear Smooth flow, virtually vibration free, stainless steel head allows additional process fluids 63 dBA 3 bar, 30 psi Water, glycol/water, alcohol/water, DI water, HFE, PAO, Fluorinert, Galden 25,000 hr MTBF 2 years
2 lpm Magnetic Drive Gear Smooth flow, virtually vibration free, stainless steel head allows additional process fluids 65 dBA 3 bar, 30 psi Water, glycol/water, alcohol/water, DI water, HFE, PAO, Fluorinert, Galden 25,000 hr MTBF 2 years
3 lpm Magnetic Drive Gear Smooth flow, virtually vibration free, stainless steel head allows additional process fluids 65 dBA 3 bar, 30 psi Water, glycol/water, alcohol/water, DI water, HFE, PAO, Fluorinert, Galden 25,000 hr MTBF 2 years
1-2 lpm Centrifugal Smooth flow, virtually vibration free, low pressure pump 1 bar (15 psi) Water, glycol/water, alcohol/water, DI water 25,000 hr MTBF 2 years
1-2 lpm Centrifugal Smooth flow, virtually vibration free, low pressure pump 1.3 bar (20 psi) Water, glycol/water, alcohol/water, DI water 25,000 hr MTBF 2 years

Pump Curves can be seen by clicking the Performance tab above

Power Cords

Options
United States & Canada
Europe
Japan
United Kingdom
Israel
Australia
Korean
China (3 prong)
NEMA 6-15 208 US Straight
NEMA L6-15 208 US Twist

Customer specifies power cord for their country. Ten standard cords are available at no extra charge. Universal input, 100 - 240VAC, 50/60 Hz.


Fittings
All options are available on process coolant lines or house water lines.

Option Purpose Tubing Size Manufacturer's Website
John Guest Simple, push-in fittings for plastic tubing 1/4", 3/8" www.johnguest.com
CPC Valved fitting; for easy disconnect and reconnect (not recommended for use with centrifugal pump due to low head pressure) 1/4", 3/8" www.colder.com A mating fitting must match Colder Products part number PLCD16004
CPC metal Toughened version of CPC fitting, chrome-plated brass 1/4", 3/8" www.colder.com A mating fitting must match Colder Products part number LCD16004
Swagelok For use with stainless steel tubing, typically semiconductor applications, very durable 1/4", 3/8" www.swagelok.com


Plumbing Packages

For convenient hookup between the ThermoCube chiller and your system.

Option Description
1/4" JG plumbing package Two four-foot long EPDM insulated hoses with two 1/4" John Guest fittings
1/4" CPC plumbing package Two four-foot long EPDM insulated hoses with two 1/4" CPC adaptor fittings



Other Options

Options Purpose
Communications R2 RS232 interface controller optional
External Liquid Filter EF External filter, 5 micron,
Attaches to chiller externally, adds approx 6" to depth
Compatible with PAO, water, glycol/water, alcohol/water, DI water
Fixed Setpoint PT Preset control temperature from -5 to +65
No user input buttons on user interface
Fixed single setpoint
Extended Low Temperature Range LT Extends lower range to -10 °C (14 °F)
Extended High Temperature Range HT Extends upper range to 65 °C (149 °F)
Vibration Reduction VD Adds sound dampening material to interior of sheet metal skins
Useful for ultra-sensitive SEMS and CCD applications to prevent vibration from traveling in fluids
Dry Contact Signals DC Dry contact alarm signals optional
Auto-Restart AR Software upgrade
Upon chiller power-up, unit automatically returns to control at last setpoint temperature (no operator input required)
DI Water Compatibility DI Electroless nickel coating on all wetted metal parts for DI water compatibility
Non-Standard Fluid Compatibility ZZ Options are automatically selected to provide compatiblity with the fluid
FL=Fluorinert/Galden/HFE
Custom Engineered Special YY Need-specific customization. Examples include
flow switches, custom software, remote temperature probe, custom pumps

end slides

Share this product