ThermoCube 300A
Air Cooled, Pressurized Gas Chiller in 300 Watt Capacity
Current Customer Applications:
- inert gas temperature control
- laboratory
- optical benches
- microenvironment temperature control
- kinetics experiments
- lens temperature control
Download PDF Brochure
Request Instant Quote for ThermoCube
Overview
Why choose ThermoCube 300A?
- Reliable, Refrigerant-Free Thermoelectric Technology: With lifetimes exceeding 200,000 hours, the thermoelectric modules at the core of this chiller make for ultra-high intrinsic reliability.
- Compact Size: just 12" (30 cm) on a side.
- Precise Temperature Control: ThermoCube 300A's digital PID control holds to ±0.2 °C, even near ambient
- Optimized for Modest Heat Loads
- Versatile: For use with clean dry air (CDA), N2, argon or other inert gases
- Energy Efficient: ThermoCube's thermoelectric modules are powered by variable voltage power supply that provides minimum power required to control temperature at set point, so ThermoCube only draws as much power as needed (typically <200 W AC)
- Whisper-Quiet: as low as 49 dBA
- Worldwide Power Compatibility, Universal Input Standard
- Easy-to-Use controller for fixed temperature control or temperature cycling
- Air-Cooled: Does not require house or facility chilled water. Can operate in any standard room, laboratory or office.
Performance

Specifications
| Operating Range: | -10 to 50 °C standard range (down to -5 °C with low temp option) (up to 65 °C with high temp option) |
Size (L x W x H): | 12.75 x 11.0 x 12.75" (32.4 x 28 x 32.4 cm) |
|
| Repeatability: | + 0.2 °C, even near ambient | Weight: | 28 lbs (12.7 kg) | |
| Cooling Capacity: | 300 W at 25 °C (25 °C ambient) | Power: | 100-240 VAC, 50 or 60 Hz, 7A -3.5A | |
| Modes: | Fixed setpoint, cycling | Standards: | CE, TUV listed to CSA/UL 61010- | |
| Noise: | 63 dBA at 3 feet (60 or 49 dBA optional) |
Alarms: |
TTL (temp and system failure), optional dry contacts optional |
|
| Coolant: | Ambient air, N2, clean dry air, argon | Communications: | RS232 | |
| Coolant Fittings: | 1/4" John Guest standard, optional CPC or Swagelok |
Warranty: |
2 years |
|
| Coolant (gas) flow rate: | Up to 300 slpm |
|
|
Configuration
The following components are included in the standard ThermoCube chiller configuration. However, we regularly work with OEM customers to develop specialized or unique ThermoCube configurations.
Capacity
| Option | Purpose | Standard Operating Temperature Range | Standard Operating Temperature Range |
| 300 A | Temperature control of compressed inert gases, heat load up to 300 W (1020 BTU/hr) | -5 to +50 °C | 41 to 122 °F |
Fans
All fans suitable for indoor, non-condensing environments
| Option | Purpose | Noise at 1 meter |
| Standard Fan | Included in base price | 60 to 63 dBA |
| Quiet Fan | Quieter, constant speed operation | 57 to 60 dBA |
| Variable Speed Fan | Variable speed operation, normal mode at 49 dBA and will increase fan speed as needed to meet setpoint | 49 to 60 dBA |
Power Cords
| Options |
| United States & Canada |
| Europe |
| Japan |
| United Kingdom |
| Israel |
| Australia |
| Korea |
| China (3 prong) |
| NEMA 6-15 208 US Straight |
| NEMA L6-15 208 US Twist |
Customer specifies power cord for their country. Ten standard cords are available at no extra charge. Universal input, 100 - 240VAC, 50/60 Hz.
Fittings
All options are available on process coolant lines or house water lines.
| Option | purpose | Tubing Size | Manufacturer's Website | |
| John Guest | Simple, push-in fittings for plastic tubing | 1/4", 3/8" | www.johnguest.com | |
| CPC | Valved fitting; for easy disconnect and reconnect (not recommended for use with centrifugal pump due to low head pressure) | 1/4", 3/8" | www.colder.com | A mating fitting must match Colder Products part number PLCD16004 |
| CPC metal | Toughened version of CPC fitting, chrome-plated brass | 1/4" | www.colder.com | A mating fitting must match Colder Products part number LCD16004 |
| Swagelok | For use with stainless steel tubing, typically semiconductor applications, very durable | 1/4", 3/8" | www.swagelok.com |
Other Options
| Option | Purpose | |
| Communications | R2 | RS232 interface controller |
| External Liquid Filter | EF | External filter, 5 micron, Attaches to chiller externally, adds approx 6" to depth Compatible with PAO, water, glycol/water, alcohol/water, DI water |
| External Air Filter | AF | External air intake filter Mounted onto fan intake grill, adds 1/2" to width of chiller Helps eliminate hair, carpet fibers, lint, dust |
| Fixed Setpoint | PT | Preset control temperature from -5 to +65 No user input buttons on user interface Fixed single setpoint |
| Extended Low Temperature Range | LT | Extends lower range to -5 °C (23 °F) |
| Extended High Temperature Range | HT | Extends upper range to 65 °C (149 °F) |
| Vibration Reduction | VD | Adds sound dampening material to interior of sheet metal skins Useful for ultra-sensitive SEMS and CCD applications to prevent vibration from traveling into fluids |
| Dry Contact Signals | DC | Dry contact alarm signals |
| Auto-Restart | AR | Software upgrade Upon chiller power-up, unit automatically returns to control at last setpoint temperature (no operator input required) |
| DI Water Compatibility | DI | Electroless nickel coating on all wetted metal parts |
| Non-Standard Fluid | ZZ | Options are automatically selected to provide compatiblity with the fluid Choices: PA = PAO SI=Silicon FL=Fluorinert GA=Galden |
| Custom Engineered Special | YY | Need-specific customization. Examples include flow switches, custom software, remote temperature probe, custom pumps |