ThermoCube 300A

Thermocube by Solid State Cooling SystemsAir Cooled, Pressurized Gas Chiller in 300 Watt Capacity

 

Current Customer Applications:

  • inert gas temperature control
  • laboratory
  • optical benches
  • microenvironment temperature control
  • kinetics experiments
  • lens temperature control


 Solid State Cooling Systems


Download PDF Brochure
Request Instant Quote for ThermoCube

 

Overview

Why choose ThermoCube 300A?

  • Reliable, Refrigerant-Free Thermoelectric Technology: With lifetimes exceeding 200,000 hours, the thermoelectric modules at the core of this chiller make for ultra-high intrinsic reliability. 
  • Compact Size: just 12" (30 cm) on a side.
  • Precise Temperature Control: ThermoCube 300A's digital PID control holds to ±0.2 °C, even near ambient 
  • Optimized for Modest Heat Loads
  • Versatile: For use with clean dry air (CDA), N2, argon or other inert gases 
  • Energy Efficient: ThermoCube's thermoelectric modules are powered by variable voltage power supply that provides minimum power required to control temperature at set point, so ThermoCube only draws as much power as needed (typically <200 W AC) 
  • Whisper-Quiet: as low as 49 dBA 
  • Worldwide Power Compatibility, Universal Input Standard 
  • Easy-to-Use controller for fixed temperature control or temperature cycling 
  • Air-Cooled: Does not require house or facility chilled water. Can operate in any standard room, laboratory or office.

Performance

tcube 300a coolingcapacitycurves lowres

Specifications

Operating Range: -10 to 50 °C standard range
(down to -5 °C with low temp option)
(up to 65 °C with high temp option)
            Size (L x W x H): 12.75 x 11.0 x 12.75"
(32.4 x 28 x 32.4 cm)
Repeatability: + 0.2 °C, even near ambient Weight: 28 lbs (12.7 kg)
Cooling Capacity: 300 W at 25 °C (25 °C ambient) Power: 100-240 VAC, 50 or 60 Hz, 7A -3.5A
Modes: Fixed setpoint, cycling Standards: CE, TUV listed to CSA/UL 61010-
Noise: 63 dBA at 3 feet
(60 or 49 dBA optional)

Alarms:

TTL (temp and system failure), optional dry contacts optional

Coolant: Ambient air, N2, clean dry air, argon Communications: RS232
Coolant Fittings: 1/4" John Guest standard, optional CPC or Swagelok

Warranty:

2 years

Coolant (gas) flow rate: Up to 300 slpm

 

 

Configuration

The following components are included in the standard ThermoCube chiller configuration. However, we regularly work with OEM customers to develop specialized or unique ThermoCube configurations.

Capacity

Option Purpose Standard Operating Temperature Range Standard Operating Temperature Range
300 A Temperature control of compressed inert gases, heat load up to 300 W (1020 BTU/hr) -5 to +50 °C 41 to 122 °F

Fans
All fans suitable for indoor, non-condensing environments

Option Purpose Noise at 1 meter
Standard Fan Included in base price 60 to 63 dBA
Quiet Fan Quieter, constant speed operation 57 to 60 dBA
Variable Speed Fan Variable speed operation, normal mode at 49 dBA and will increase fan speed as needed to meet setpoint 49 to 60 dBA



Power Cords

Options
United States & Canada
Europe
Japan
United Kingdom
Israel
Australia
Korea
China (3 prong)
NEMA 6-15 208 US Straight
NEMA L6-15 208 US Twist

Customer specifies power cord for their country. Ten standard cords are available at no extra charge. Universal input, 100 - 240VAC, 50/60 Hz.


Fittings
All options are available on process coolant lines or house water lines.

Option purpose Tubing Size Manufacturer's Website
John Guest Simple, push-in fittings for plastic tubing 1/4", 3/8" www.johnguest.com
CPC Valved fitting; for easy disconnect and reconnect (not recommended for use with centrifugal pump due to low head pressure) 1/4", 3/8" www.colder.com A mating fitting must match Colder Products part number PLCD16004
CPC metal Toughened version of CPC fitting, chrome-plated brass 1/4" www.colder.com A mating fitting must match Colder Products part number LCD16004
Swagelok For use with stainless steel tubing, typically semiconductor applications, very durable 1/4", 3/8" www.swagelok.com



Other Options

Option   Purpose
Communications R2 RS232 interface controller
External Liquid Filter EF External filter, 5 micron,
Attaches to chiller externally, adds approx 6" to depth
Compatible with PAO, water, glycol/water, alcohol/water, DI water
External Air Filter AF External air intake filter
Mounted onto fan intake grill, adds 1/2" to width of chiller
Helps eliminate hair, carpet fibers, lint, dust
Fixed Setpoint PT Preset control temperature from -5 to +65
No user input buttons on user interface
Fixed single setpoint
Extended Low Temperature Range LT Extends lower range to -5 °C (23 °F)
Extended High Temperature Range HT Extends upper range to 65 °C (149 °F)
Vibration Reduction VD Adds sound dampening material to interior of sheet metal skins
Useful for ultra-sensitive SEMS and CCD applications to prevent vibration from traveling into fluids
Dry Contact Signals DC Dry contact alarm signals
Auto-Restart AR Software upgrade
Upon chiller power-up, unit automatically returns to control at last setpoint temperature (no operator input required)
DI Water Compatibility DI Electroless nickel coating on all wetted metal parts
Non-Standard Fluid ZZ Options are automatically selected to provide compatiblity with the fluid
Choices: PA = PAO
SI=Silicon
FL=Fluorinert
GA=Galden
Custom Engineered Special YY Need-specific customization. Examples include
flow switches, custom software, remote temperature probe, custom pumps

end slides